3''-Crimping-Machine

детайли


Part no.: YHHC-48B
System: computer controlled system
Standard dies: 16 sets of dies from 1/4’’ to 3’’
Voltage: 380V/50HZ; if other voltage required, please advise us.
Stock available: we have kept many types in stock, then we can ensure the fast delivery.

Таблица с технически данни

ТипYHHC-48B (computer system controlled)
Crimping rangeΦ6—φ76  4SP
MotorY-4/4kw
Voltage380V*50HZ
Capacity of oil pump19L/min
Систематично налягане30MPa
Hydraulic oilWinter :YB-N32
Summer :YB-N46
Oil tank volume480×440×360mm3
L*W*H800×650×1350(mm)
Crimping pressure903T

Нашата услуга


1.Имаме много агенти по целия свят, така че можете да се свържете с нашия агент, за да закупите нашите продукти
2.Technical support any time, Our engineer cellphone:
+86-15158322675
3. Гаранционно време 3 години, гаранционната карта с машината заедно към вас.
4.Поставете видео, за да научите как да използвате машини.
5. Door to door service, we are in charge of sending the machine to your office, after payment.fitting ferrule crimping machine
6.можем да проектираме машини като своя чертеж и изисквания. OEM

ЧЗВ


Trouble phenomena

Trouble reason

Eliminating method

Machine has not action

Oil tank has not been filled with oil

Fill oil as per requirement

Motor rotation direction is not correct

Regulate two phase lines

Electric trouble

Overhaul electric circuits

Scale is damaged

The scale is fastened on the oil cylinder end face by the screw

Regulate the scale as per the instruction to make scale to telescope freely

Conductor at scale location is connected with scale

Anew connect the scale conductor to make it to be insulated from scale base

Electric trouble

Overhaul electric circuits and electric elements

Scale conductor cutting

Anew connect scale

System pressure is excessively low

Adjust buckling pressure-regulating valve

No buckling

The valve core of solenoid reversal valve is seizured by foreign matters

Dismount solenoid reversal valve, use gasoline to clean the valve core.

Electric trouble

Overhaul electric circuits

Mould is not opened

Opening mould pressure is excessively low

Adjust opening mould pressure regulating valve

Electric trouble

Overhaul electric circuits

Lubrication is poor

Smear grease on the working inclined face of mould base

Oil leakage

Joint is not tightened closely

Tighten the oil pipe joint

Sealing washer is damaged.

Replace sealing washer