YHHC-91A is a crimping machine for hydraulic hose sizes from 1/8’’ to 2’’. It is sold with 10 sets of standard dies that is used for different size of hoses. There are lubricated groove on the frictional surface, in which self-supported oil can come true. YH ensure quality machine provided and after-sales service is available.
детайли
Part no.: YHHC-91A
Two types of speed, using variable pump, power saved and high speed
Dies changed in axis position, and special-shaped big bend can be fitted
There are lubricated groove on the frictional surface, in which self-supported oil can come true
Наличност: Налични
Shipping term: Within 10 days after receive the payment or according to invoice made
YH Advantage: Quality updated; Reasonable price; Nice service
Таблица с технически данни
Обхват на кримпване | 1/8 '' - 2 '' 4SP |
Стандартно напрежение и мотор | 380V / 3KW |
Отваряне без матрици | Φ119mm |
отвор | ≥25mm |
Опционално напрежение и мотор | 220V / 2.2kW |
№ на стандартния комплект за матрици | 10 комплекта |
Систематично налягане | 30MPa |
тегло | 296KGS |
Обем (L * W * Н) | 800 мм * * шестстотин тридесет и пет милиарда mm 1376mm |
ЧЗВ
Trouble phenomena | Trouble reason | Eliminating method |
Machine has not action | Oil tank has not been filled with oil | Fill oil as per requirement |
Motor rotation direction is not correct | Regulate two phase lines | |
Electric trouble | Overhaul electric circuits | |
Scale is damaged | The scale is fastened on the oil cylinder end face by the screw | Regulate the scale as per the instruction to make scale to telescope freely |
Conductor at scale location is connected with scale | Anew connect the scale conductor to make it to be insulated from scale base | |
Electric trouble | Overhaul electric circuits and electric elements | |
Scale conductor cutting | Anew connect scale | |
System pressure is excessively low | Adjust buckling pressure-regulating valve | |
No buckling | The valve core of solenoid reversal valve is seizured by foreign matters | Dismount solenoid reversal valve, use gasoline to clean the valve core. |
Electric trouble | Overhaul electric circuits | |
Mould is not opened | Opening mould pressure is excessively low | Adjust opening mould pressure regulating valve |
Electric trouble | Overhaul electric circuits | |
Lubrication is poor | Smear grease on the working inclined face of mould base | |
Oil leakage | Joint is not tightened closely | Tighten the oil pipe joint |
Sealing washer is damaged. | Replace sealing washer |